Regular maintenance and upkeep Winder
Date:2019-10-14 09:10:56 Click:
 

In order to ensure the normal operation of winding machine, in addition to follow the rules correctly, properly monitored during operation and maintenance of attention, it should also be regularly inspected, good Winder maintenance work.

This can eliminate some of the problems in time to prevent failure, to ensure safe and reliable operation of the winding machine. Regular maintenance intervals could according to the winding machine form to consider the use of the environment decision.

Periodic maintenance as follows.

①Cleaning Winder. The timely removal of Winder stands outside dust, sludge.If the used of the environment have much dusty , preferably cleaned once a day.

Check and wiping Winder terminals. Check the junction box terminal screws are loose, burns. check the fixed portion of the screw, including anchor bolts, cap screws, bearing cap screws. The loose nut tightened.

Check the transmission. Check the pulleys or couplings for cracks, damage, is firmly installed; its feeder belt buckle is intact.

Winder boot device, but also a timely wiping external dust, dirt, wipe contacts, check the wiring parts has traces of burning, the ground wire is well.

inspection and maintenance bearing. Bearing in use for some time should be cleaned, replace grease or oil. Cleaning and oil change time, should work with the winding machine, work environment, cleanliness, depending on the type of lubricant. Generally every three to six months of work, it should be cleaned once again change the grease. At higher oil temperature, or poor environmental conditions, dusty winding confidential regular cleaning, oil changes. Cleaning of rolling bearings, replace grease method has been said before, are not repeated here.

Check the insulation condition. The insulating capacity of the insulating material due to vary the degree of drying, the drying so keep the motor winding is very important. Winder wet working environment, workplace factors such as the presence of corrosive gases will destroy the electrical insulation. The most common is winding ground fault, that insulation is damaged, so and so live parts and metal parts of the cabinet should not be charged collide, the occurrence of this failure, not only affects the winding machine is working properly, but also endanger their personal safety. So winding machine in use, you should always check the insulation resistance, but also pay attention to see Winder chassis ground is

No reliable.

In addition to the above-mentioned several elements of Winder regular maintenance, overhaul once a year to run. Overhaul aims of Winder conduct a thorough and comprehensive inspection, maintenance, additions Winder missing, worn components, the complete elimination of Winder and outside dust, dirt, check the insulation, cleaning bearings and check wear. Find problems and timely treatment.